Postbuckling Analysis of a Hinged Cylindrical Shell
Application ID: 10257
The model studied is a benchmark for a hinged cylindrical panel subjected to a point load at its center. A linear buckling analysis predicts the critical buckling load. Such an analysis will however not give any information about what happens at loads higher than the critical load. Tracing the solution after the critical load is called a postbuckling analysis. This model uses the Shell interface.
This model example illustrates applications of this type that would nominally be built using the following products:
however, additional products may be required to completely define and model it. Furthermore, this example may also be defined and modeled using components from the following product combinations:
The combination of COMSOL® products required to model your application depends on several factors and may include boundary conditions, material properties, physics interfaces, and part libraries. Particular functionality may be common to several products. To determine the right combination of products for your modeling needs, review the Specification Chart and make use of a free evaluation license. The COMSOL Sales and Support teams are available for answering any questions you may have regarding this.